Magnitude Specifications Region: Bandpass
IIR |
FIR |
Butterworth |
Equiripple |
Chebyshev Type I |
Least-Squares |
Chebyshev Type II |
Window |
Elliptic |
Constr. Least-Squares |
If Specify order is selected in the Filter Order region, the attenuation at the cutoff frequency is fixed at 3 dB (half the passband power).
If Minimum order is selected in the Filter Order region, select the units for magnitude response characteristics from the Units list:
Specify the magnitude response characteristics in the text boxes:
If Specify order is selected in the Filter Order region, specify the passband ripple (Apass) in decibels.
If Minimum order is selected in the Filter Order region, select the units for magnitude response characteristics from the Units list:
Specify the following magnitude response characteristics in the text boxes:
If Specify order is selected in the Filter Order region, specify the stopband attenuation (Astop or Estop) in decibels.
If Minimum order is selected in the Filter Order region, select the units for magnitude response characteristics from the Units list:
Specify the following magnitude response characteristics in the text boxes:
Select the units for magnitude response characteristics from the Units list:
If Specify order is selected in the Filter Order region, specify the following magnitude response characteristics (in dB) in the text boxes:
If Minimum order is selected in the Filter Order region, specify the following magnitude response characteristics (in dB) in the text boxes:
If Specify order is selected in the Filter Order region, specify the following relative weights in the text boxes:
If Minimum order is selected in the Filter Order region, select the units for magnitude response characteristics from the Units list:
Specify the following magnitude response characteristics in the text boxes:
Specify the magnitude weights, as linear multipliers, in the text boxes:
If Specify order is selected in the Filter Order region, the attenuation at the cutoff frequency is fixed at 6 dB (half the passband gain).
For the Kaiser window option, if Minimum order is selected in the Filter Order region, select the units for magnitude response characteristics from the Units list:
Specify the following magnitude response characteristics in the text boxes:
Specify the magnitude response characteristics in the text boxes:
Magnitude Specifications Region: Highpass | Magnitude Specifications Region: Bandstop |